EH Series
100 Watt Regulated
High Voltage
DC Power
Supplies |

PDF Print Version
HTML Print Version
|
 |
| Models from 0-1 kV DC through 0-60 kV DC |
|
Fully compliant with the European
harmonized EMI directive, EN50082-2, and with the low voltage (safety) directive, 73/23/EEC.
Line harmonics are within the European harmonized standard, EN61000-3-2 specifications. |
|
- Laboratory Performance
- Enhanced Features
- Economical Price
|
The EH Series was
designed for the user who requires premium performance coupled with "application flexible" features. The
result...high voltage power supplies of superior quality...at an affordable price. Replete with standard
features, there are no hidden extras.
Features
Unique "True Load Monitor" enables the load current to be monitored
accurately with respect to ground. This eliminates the need to break the common/ground connection, and/or to program the
output with an isolated source.
Low Ripple. Better than 0.03% at full load.
Air Insulated. As in all standard Glassman power supplies these units employ
"air" as the dielectric medium. No oil or encapsulation to impede serviceability or increase weight.
Low Stored Energy. Less than 800 millijoules for most models.
Constant Voltage Constant Current Operation. Automatic crossover from voltage or
current regulated mode dependent on the load conditions.
Tight Regulation. Voltage regulation better than 0.005% line and load; current
regulation better than 0.05% from short circuit to rated voltage.
Fast Transient Response. Less than 3 milliseconds for a 50% load transient.
Front Panel Elements Include: Ten turn voltage and current controls with
locking vernier dials, accurate 2 1/2" analog displays both voltage and current, illuminated AC power on/off switch.
Remote Control Facilities Include: Output voltage and current program/monitor
terminals, high voltage enable/disable, safety interlock terminals, and + 10 volt reference source.
Warranty. Standard power supplies are warranted for three years; OEM and modified power
supplies are warranted for one year. A formal warranty statement is available.
Specifications
(From 5% to 100% rated voltage. All units operate down to zero output with very
slight degradation of performance.)
Input: 105-125V RMS 48-63Hz, single phase, less than 1.5 amperes. Input
connector per IEC 320 with mating line cord provided. 105-125V RMS 48-63Hz, single phase, less than 1.5 amperes. Input
connector per IEC 320 with mating line cord provided.
Efficiency: Better than 75% at full load. Better than 75% at full load.
Output: Continuous, stable adjustment, from 0 to rated voltage or current by panel
mounted 10-turn potentiometers with 0.05% resolution, or by external 0 to 10V signals is provided. Linearity is <1% of
rated. Accuracy is 1% of rated + 1% of setting. Repeatability is <0.1% of rated. Continuous, stable adjustment, from 0 to rated voltage or current by panel
mounted 10-turn potentiometers with 0.05% resolution, or by external 0 to 10V signals is provided. Linearity is <1% of
rated. Accuracy is 1% of rated + 1% of setting. Repeatability is <0.1% of rated.
Stored Energy: 10kV model, 200 millijoules; 50kV model, 1 joule. 10kV model, 200
millijoules; 50kV model, 1 joule.
Voltage Regulation: Better than 0.005% +1mV/mA, line and load. Better than 0.005%
+1mV/mA, line and load.
Ripple: Better than 0.03% RMS of rated voltage +0.5V at full load. Better than 0.03% RMS of rated voltage +0.5V at full load.
Current Regulation: Better than 0.05% from short circuit to rated voltage at any
set current condition.
Voltage Monitor: Zero to +10V DC signal is equivalent to zero to rated voltage.
Accuracy, 1% of rated voltage.
Current Monitor: Zero to +10V DC signal is equivalent to zero to rated current.
Accuracy, 1% of reading +0.05% of rated current (Reversible models 1% of reading +0.1% of rated).
Stability: 0.01% per hour, after 1/2 hour warm-up, 0.05% per 8 hours.
Voltage Rise/Decay Time Constant: Using either the HV (on/off) or remote voltage
control, with a 75% resistive load, the output voltage will rise or decay with a typical time constant of 60 milliseconds
(100mS maximum).
Temperature Coefficient: 0.01% per degree C.
Ambient Temperature: -20 to +60 degrees C, operating; -40 to +85 degrees C, storage.
Polarity: Available with either positive, negative, or reversible polarity with respect
to chassis ground.
Protection: Automatic current regulation protects the power supply against all
overload conditions, including arcs and short circuits. Fuses, surge limiting resistors, and low energy components provide
the ultimate protection.
Accessories: Detachable 8 foot shielded high voltage coaxial cable (see
Models chart for cable type) and 6 foot detachable line cord are provided.
Remote Controls: Common, +10 volt reference, interlock, current monitor,
current program, voltage monitor, voltage program, HV enable/disable, and ground provided on a rear panel terminal
block.
External Interlock: Open off, close on.
HV Enable/Disable: 0-1.5V off, 2.5-15V on.
Options
| Symbol |
Description |
| 100 |
Rated for 90 to 110 volts RMS. 48-420 Hz. |
| 200 |
Rated for 210 to 250 volts RMS. 48-420 Hz. |
| CTS |
Current
trip. Power supply trips off when the load current reaches the programmed level. This option has a
rear panel switch that selects either "trip" operation or current limiting. |
| DM |
3-1/2 digit LCD panel meters. |
| 5VC |
0-5V Voltage and Current Program/Monitor. |
| GE9 |
RS-232 control and monitor. |
Models
Click on the model number below to request a quote and
for complete ordering part number.
Outline Drawing

|