EK Series
600W Regulated
High Voltage
DC Power Supplies |

PDF Print Version
HTML Print Version
|
 |
| Models from 0 to 1 kV through 0 to 60 kV, 3.50" H x 20.5" D, 20 lbs |
|
The EK Series are fully compliant with
the European Harmonized EMI Directive EN50082-2 and with the European Low Voltage (Safety) Directive, 73/23/EEC.
|
|
- 1 kV to 60 kV Rack Mount
- 3.5 Inch Panel Height
- Laboratory Performance
- CE and Semi S2-93 Compliant
|
The EK family of power supplies is a sophisticated, 600-watt DC power supply with low ripple and noise. They are air insulated, fast response units, with tight regulation and extremely low arc discharge currents. The EK series offers a voltage range from 1 to 60kV while providing low ripple and noise, tight regulation, and fast response time in a 3.5” high rack mount unit.
The 600W EK series features two notable technology benefits 1: Glassman’s proprietary air-insulation technology—where air is used as the primary dielectric medium, in comparison to competitive models that utilize silicon rubber, epoxy or oil. Air offers distinct advantages from both a long-term reliability standpoint and serviceability over the extended life of the product. 2: Proprietary arc sensing and quench circuitry that will suppress arcing conditions that can occur regularly in DC power supply applications limiting the amount of energy that is being fed to the source as well as providing maximum safety and protection for both the power supply and customer load.
This feature makes the EK ideal for use with Magnetron sputtering, X-ray, Electron Gun and Ion source applications to name a few. It can also be utilized as a Laboratory or bench-top high voltage power supply.
The EK also offers a Constant Power option that can suit a host of system control requirements. It is CE Mark certified and as an option offers power factor correction for applications or customers that require this feature.
Features
Arc Quench. The HV output is inhibited for a short period after each
load arc to help extinguish the arc.
Arc Sensing. Internal circuitry constantly senses and integrates arcs
that occur over a given time. In the event a system or load arcing problem develops and exceeds factory-set
parameters, the power supply will cycle off in an attempt to clear the fault and then automatically restart
after a preset "off dwell time".
Pulse-Width Modulation. Off-the-line pulse-width modulation provides
high efficiency and a reduced parts count for improved reliability.
Low Ripple. Typically, ripple is less than 0.02% RMS of rated voltage
at full load.
Air Insulated. The EK Series features "air" as the primary
dielectric medium. No oil or encapsulation is used to impede serviceability or increase weight.
Constant Voltage/Constant Current Operation. Automatic crossover from
constant-voltage to constant-current regulation provides protection against overloads, arcs, and short circuits.
Redundant Thermal Overload Protection. Thermostats and fan RPM sensing
shut down the power supply due to over temperature or reduced fan speeds.
Tight Regulation. Voltage regulation is better than 0.005% for
allowable line and load variations. Current regulation is better than 0.1% from short circuit to rated
voltage.
Warranty. Standard power supplies are warranted for three years;
OEM and modified power supplies are warranted for one year. A formal warranty statement is available.
Specifications
(Specifications apply from 5% to 100% rated voltage. Operation is guaranteed
down to zero voltage with a slight degradation of performance.)
Input: 102 - 132 V RMS, single-phase, 48-63 Hz, 1200 VA maximum at full
load. Connector per IEC 320/VI with mating line cord, terminated with NEMA 5 -15 plug.
Efficiency: Typically greater than 85% at full load.
Output: Continuous, stable, adjustment
from 0 to rated voltage or current by panel mounted 10-turn potentiometers with
0.05% resolution, or by external 0 to 10 V signals is provided. Voltage accuracy
is 0.5% of setting + 0.2% of rated.
Static Voltage Regulation: Better than ±0.005% for specified line
variations and 0.005% + 0.5 mV/mA for no load to full load variations.
Dynamic Voltage Regulation: For load
transients from 10% to 99% and 99% to 10%, typical deviation is less than 2% of
rated output voltage with recovery to within 1% in 500 us and recovery to within
0.1% in 1 ms.
Ripple: Better than 0.025% of rated voltage + 0.5 V RMS at full load.
Current Regulation: When in current regulation mode, better than
0.1% from short circuit to rated voltage at any load condition.
Voltage Monitor: 0 to +10 V equivalent to 0 to rated voltage.
Accuracy, 0.5% reading + 0.2% rated. Impedance is 10 K Ohm.
Current Monitor: 0 to +10 V equivalent to 0 to rated current.
Accuracy, 1% reading + 0.05% rated for fixed polarity, 1% reading + 0.1% rated for reversible polarity.
Impedance is 10 K Ohm.
Stability: 0.01% per hour after 1/2 hour warm-up, 0.05% per
8 hours.
Voltage Rise/Decay Time Constant: The voltage rise time constant
is 50 ms typical for all models using either HV enable or remote programming control. The voltage decay
time constant is 50 ms with a 30% resistive load for 8 kV to 60 kV models and 50 ms with a 10% resistive
load for 1 kV to 6 kV models.
Temperature Coefficient: 0.01% /°C.
Ambient Temperature: -20 to +40° C, operating; -40 to +85° C, storage.
Polarity: Available with either positive, negative or reversible
polarity with respect to chassis ground.
Protection: Automatic current regulation protects against all
overloads, including arcs and short circuits. Thermal switches and RPM sensing fans protect against
thermal overload. Fuses, surge-limiting resistors, and low energy components provide ultimate protection.
Arc Quench: An arc quench feature provides sensing of each load
arc and quickly inhibits the HV output for approximately 20 ms after each arc. Standard on 8 - 60 kV models;
optional on 1- 6 kV models.
Arc Sensing: Internal circuitry senses the number of arcs caused
by external load discharges. If the rate of consecutive arcs exceeds approximately one arc per second
for five arcs, the supply will turn off for approximately 5 seconds to allow clearance of the fault.
After this period the supply will automatically return to the programmed kV value with the rise time
constant indicated. If the load fault still exists the above cycle will repeat. Standard on 8 - 60 kV
models; optional on 1- 6 kV models.
External Interlock: Open = off, closed = on. Normally latching
except for blank front panel version where it is non-latching.
Front Panel Elements. The front panel contains all local control
functions. These control functions are: AC power on/off switch and pilot light, separate 10-turn controls
with locking vernier dials used to set voltage and current levels, and a high voltage ON switch. LED's
indicate when high voltage is on, output polarity, and whether the supply is operating in a voltage or
current regulating mode. Output levels are indicated by voltage and current digital meters.
Rear Panel Elements. AC power entry connector, fuses, power on
indicator, ground stud, HV output connector, and remote interface terminal strip.
The signals provided on the remote interface terminal strip are as
follows:
- Inputs: Safety interlock, output voltage and current program signals,
and high voltage enable.
- Outputs: Output voltage and current monitor signals, and a +10 V
reference source.
Signal common and ground reference terminals are also provided.
Remote HV Enable/Disable:
0 - 1.5 V = OFF,
2.5 - 15 V = ON.
Accessories: Detachable, 8 foot, shielded high voltage coaxial
cable (see models chart for cable type) and 6 foot detachable line cord are provided.
Weight: Approximately 20 lbs.
Options
| Symbol |
Description |
| 100 |
100 VAC ± 10%, 48 -63 Hz, NEMA 5-15 plug. |
| 200 |
200 VAC ± 10%, 48 - 63 Hz, NEMA
6-15 plug. De-rate output current by 10% when combined with PFC option. |
| 220 |
200 - 264 VAC input, 48-63 Hz. NEMA 6-15 plug. |
| PFC |
Power Factor Corrected. AC Input
line rated for 198 - 264 VAC, 48 - 63 Hz, 800 VA maximum. Active correction circuitry achieves an
input line current harmonic content well below the maximum specified in EN61000-3-2. |
| AM |
Dual analog front panel meters. |
| NC |
Blank front panel, power switch only. |
| SS |
Slow start ramp. Specify standard
times of 1, 2, 3, 5, 10, 15, 20 or 30 sec. +/-20%. |
| CT |
Current trip. The HV output will
disable and latch off when the load current reaches the programmed current level. Reset is accomplished
by either cycling the AC power/HV ON switches, or by toggling the HV enable signal. A switch located on
the rear panel allows the selection of constant current, or current trip. |
| ZR |
Zero start interlock. Voltage
control, local or remote, must be at zero before the HV will enable. |
| 5VC |
0 - 5 V voltage and current program/monitor. |
| ARC |
Arc
count and quench as described in the specifications for 1 - 6 kV models. |
| HVS |
High
voltage status indicator. Open collector with a 5K ohm pull up to +15VDC
that is high when the HV is enabled. |
| GE9 |
RS-232 control and monitor. |
Models
Click on the model number below to request a quote and
for complete ordering part number.
Outline Drawing

|