| Models from 0 to 1kV through 0 to 75kV, 3.5 inch panel height 18 pounds. |
|
| Fully compliant with the European
harmonized EMI directive, EN50082-2, and with the low voltage (safety) directive,
73/23/EEC. |
|
- Laboratory Performance
- Enhanced Features
- Economical Price
|
The ER Series models are sophisticated, medium power, high
voltage power supplies. The "designed in" versatility of this standard product
line finds itself at home in most applications/environments. With three control panel
configurations...analog, digital or blank...and a full complement of standard remote
controls, you might think high price. Not in Glassman's case, just high quality.
Features
Air Insulated. As in all standard Glassman power supplies, the ER
Series features "air" as the primary dielectric medium. No oil or encapsulation to impede
serviceability or increase weight.
Constant Voltage/Constant Current Operation. Automatic crossover
from voltage or current regulated mode dependent on the load conditions.
Low Ripple. Better than 0.02% of rated voltage at full load.
Tight Regulation. Voltage regulation better than 0.005% line or
load: current regulation better than 0.05% from short circuit to rated voltage.
Fast Transient Response. Less than 3 milliseconds for a
50% load transient.
Front Panel Controls (Analog and Digital Versions). Ten-turn voltage
and current controls with locking vernier dials. AC power ON/OFF and high voltage enable switches.
Remote Control Facilities.As standard, all ER Series power supplies
provide output voltage and current program/monitor terminals, TTL high voltage enable/disable, safety
interlock terminals, and a +10 volt reference source.
Small Size and Weight. ER Series power supplies consume only
3.5" of vertical panel height. Total weight is 18 pounds.
Warranty. Standard power supplies are warranted for three years;
OEM and modified power supplies are warranted for one year. A formal warranty statement is available.
Specifications
(From 5% to 100% rated voltage. All units operate down to zero output
with very slight degradation of performance.)
Input: 105-125 V RMS, 48-63 Hz single phase, <6 A. Connector
per IEC 320 with mating line cord.
Efficiency: Typically 85% at full load.
Output: Continuous, stable adjustment, from 0 to rated voltage or
current by panel mounted 10-turn potentiometers with 0.05% resolution, or by external 0 + 10V signals is
provided. Linearity is <1% of rated. Accuracy is 1% of rated + 1% of setting. Repeatability is
<0.1% of rated.
Stored Energy: 20 kV model, 1.5 joules; 60 kV model, <4 joules.
Voltage Regulation: <0.005% +1mV/mA, line and load.
Ripple: <0.02% RMS of rated voltage +0.5V at full load; models
1.5kV and lower, 400mV (500mV Japan).
Current Regulation: <0.05% from short circuit to rated voltage
at any set current.
Voltage Monitor: 0 to +10 V DC for zero to rated current. Accuracy,
1% of reading + .1% of rated voltage.
Current Monitor: 0 to + 10 V DC for zero to rated current. Accuracy,
1% of reading + .05% of rated current.
Stability: 0.01% per hour after 1/2 hour warm-up, 0.05% per 8 hours.
Voltage Rise/Decay Time Constant: Typically 50 ms rise or decay time
constant (300 ms for 75 kV model) using HV (on/off) or remote voltage control with 75% resistive load.
Temperature Coefficient: 0.01%/°C.
Ambient Temperature: -20 to +40°C operating, -40 to +85°C storage.
Polarity: Positive, negative, or reversible with respect to chassis
ground.
Protection: Automatic current regulation protects against all
overloads, including arcs and short circuits. Fuses, surge-limiting resistors, and low-energy components
provide ultimate protection.
Accessories: Detachable 8-foot shielded HV cable (see Model Chart for
cable type) and 6 foot detachable line cord provided.
Remote Controls: Common, +10 V reference, interlock, current monitor,
current program, voltage monitor, voltage program, TTL, and ground, provided on a rear panel mounted terminal
block.
External Interlock: Open off, closed on. Normally latching except for
blank front panel version where it is non-latching.
HV Enable/Disable: 0-1.5 V off, 2.5-15 V on.
Options
| Symbol |
Description |
| 100 |
100 V input, rated 90-110 V RMS, 48-63 Hz. |
| 220 |
220 V input, rated 200-264 V R MS, 48-63 Hz. |
| 400 |
48-420 Hz, available on standard model
and options 100 and 220. |
| DM |
3-1/2 digit LCD panel meters. |
| NC |
Blank front panel (power switch only). |
| CT |
Current trip. Power supply trips off when the load
current reaches the programmed level. This option has a rear panel switch that selects either
"trip" operation or current limiting. |
| ZR |
Zero start interlock. Voltage control must be at zero
before accepting an enable signal. |
| SS |
Slow start ramp of up to 30 seconds available.
Specify time. |
| GE9 |
RS-232 control and monitor. |
Models
Click on the model number below to request a quote and
for complete ordering part number.
Outline Drawing

|