Glassman High Voltage is a leading designer and manufacturer of High Voltage power supplies/DC power supplies for the High Voltage and Vacuum Process equipment market segments. A Glassman DC power supply can range in output from 15W-50kW with output voltages operating down to 50V thru 400kV.  A High Voltage power supply of this type can be offered in modular or Rack-mount configuration as well as special packaging to meet customer-specific mechanical requirements. Most Glassman DC power supplies are offered utilizing proprietary Air Insulation dielectric technology. Air poses numerous reliability and serviceability benefits in comparison to competing solid and liquid dielectric technologies.
home
about us
products
contact us
technology
opportunities
site map
search
request info
warranty

Glassman HV Catalog

request quote

request short
form catalog

download our
standard catalog

Recent Glassman Ads

 Product Locator:    

EW Series
Extended Current*
500 Watt
Regulated
High Voltage
DC Power
Supplies


PDF Print Version

HTML Print Version

EW Series HV Power Supply
Models from 0 to 1 kV through 0 to 60 kV
Fully compliant with the European harmonized EMI directive, EN50082-2, and with the low voltage (safety) directive, 73/23/EEC.
  • Up to 60kV
  • 3.5 Inch Panel Height
  • Less than 18 pounds
  • Laboratory Performance
  • Enhanced Features

The EW Series is a 500 watt regulated high voltage DC power supply with an important difference… maximum current ratings are equivalent to a 600 W supply! This maximum current, which is available for all output voltages up to 84% of rated voltage, should be of significant interest for many applications. The EW is offered with dual analog voltage and current meters or, optionally, with dual digital meters or a blank panel for OEM/systems applications.
Features Specifications Options Models Outline


Features

*Extended Current. EW Series models have maximum current ratings that are equivalent to a 600 W supply. These currents are available up to 84% of rated output voltage. Above this point, current is linearly derated to maintain a constant 500 W maximum output.

Pulse-Width Modulation. Off-the-line pulse-width modulation provides high efficiency and a reduced parts count for improved reliability.

Air Insulated. The EW Series features "air" as the primary dielectric medium. No oil or encapsulation is used to impede serviceability or increase weight.

Constant Voltage/Constant Current Operation. Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs, and short circuits.

Low Ripple. Ripple is typically less than 0.02% of rated voltage at full load.

Tight Regulation. Voltage regulation is better than 0.005% for allowable line and load variations. Current regulation is better than 0.5% from short circuit to rated voltage.

Front Panel Controls (Analog and Digital Versions.) Separate 10-turn controls with locking vernier dials are used to set voltage and current levels. A high voltage enable switch and an AC power on/off switch complete the panel controls. L.E.D.'s indicate when high voltage is on, the output polarity, and whether the supply is operating in a voltage or current regulating mode. For the blank panel version, only a power on/off switch is provided on the panel.

Remote Control Facilities. As standard, all EW Series supplies output voltage and current program/monitor terminals, TTL high voltage enable/disable, safety interlock terminals, and a + 10 volt reference source.

Small Size and Weight. EW Series power supplies occupy only 3.5 inches of panel height. Net weight is less than 18 pounds.

Warranty. Standard power supplies are warranted for three years; OEM and modified power supplies are warranted for one year. A formal warranty statement is available.


Specifications

(From 5% to 100% rated voltage. All units operate down to zero output with very slight degradation of performance.)

Input: 102-132 V RMS, single-phase, 48-63 Hz, <10A. Connector per IEC 320 with mating line cord, terminated with NEMA 5-15 plug.

Efficiency: Typically 85% at full load.

Output: Continuous, stable adjustment, from 0 to rated voltage or current by panel mounted 10-turn potentiometers with 0.05% resolution, or by external 0 to 10V signals is provided. Linearity is < 1% of rated. Accuracy is 1% of rated +1% of setting. Repeatability is <0.1% of rated.

Stored Energy: <1.5 Joules, 20 kV; <4 Joules, 60 kV.

Voltage Regulation: Better than 0.005% for specified line variations and 0.005% + 1 mV/mA for load variations.

Ripple: <0.02% of rated voltage + 0.5 V RMS at full load.

Current Regulation: Better than 0.05% from short circuit to rated voltage at any load condition.

Voltage Monitor: 0 to + 10 V equivalent to 0 to rated voltage. Accuracy, 1% reading + 1% rated.

Current Monitor: 0 to + 10 V equivalent to 0 to rated current. Accuracy, 1% reading +0.05% rated for single polarity, 1% reading + 0.1% rated for reversible polarity.

Stability: 0.01% per hour after1/2 hour warmup, 0.05% per 8 hours.

Voltage Rise/Decay Time Constant: 50 ms typical with a 30% resistive load using either HV on/off or remote programming control.

Temperature Coefficient: 0.01% per degree C.

Ambient Temperature: -20 to +40 degree C, operating; -40 to +85 degree C, storage.

Polarity: Available with either positive, negative, or reversible polarity with respect to chassis ground.

Protection: Automatic current regulation protects against all overloads, including arcs and shorts. Fuses, surge-limiting resistors, and low energy components provide ultimate protection.

Remote Controls: Terminal block is provided for all remote functions, including common, +10 V reference, interlock, voltage and current program/monitor, TTL, ground, and local control, provided on a rear panel terminal block.

External Interlock: Open off, closed on. Normally latching except for blank panel version where it is non-latching.

HV Enable/Disable: 0-1.5 V off, 2.5-15 V on.


Options

Symbol Description
100 90-116 V input, 48-63 Hz. NEMA 5-15 plug.
200 180-232 V input, 48-63 Hz. NEMA 6-15 plug.
220 200-264 V input, 48-63 Hz. NEMA 6-15 plug.
400 48-420 Hz input.
DM 3-1/2 digit LCD panel meters.
NC Blank front panel, power switch only.
CT Current trip. Power supply trips off when the load current reaches the programmed level. This option has a rear panel switch that selects either "trip" operation or current limiting.
ZR Zero start interlock. Voltage control, local or remote, must be at zero before accepting an enable signal.
SS Slow start ramp. Specify standard times of 1, 2, 3, 5, 10, 15, 20, or 30s +/-20%
5VC 0-5 V voltage and current program/monitor.
GE9 RS-232 control and monitor.


Models

Click on the model number below to request a quote and for complete ordering part number.

Positive
Polarity
Negative
Polarity
Reversible
Polarity
Output
Voltage
(kV)
Output
Current
(mA)
Output
Cable
Panel Height
(in)
Reversible
only
EW1R600 0-1 0-600 RG-59 3.5
EW1.5R400 0-1.5 0-400 RG-59 3.5
EW2R300 0-2 0-300 RG-59 3.5
EW3R200 0-3 0-200 RG-59 3.5
EW5R120 0-5 0-120 RG-59 3.5
EW7P85 EW7N85 EW7R85 0-7 0-85 RG-8U 3.5
EW10P60 EW10N60 EW10R60 0-10 0-60 RG-8U 3.5
EW15P40 EW15N40 EW15R40 0-15 0-40 RG-8U 3.5
EW20P30 EW20N30 EW20R30 0-20 0-30 RG8U 3.5
EW25P24 EW25N24 EW25R24 0-25 0-24 RG-8U 3.5
EW30P20 EW30N20 EW30R20 0-30 0-20 RG-8U 3.5
EW40P15 EW40N15 EW40R15 0-40 0-15 RG-8U 3.5
EW50P12 EW50N12 EW50R12 0-50 0-12 RG-8U 3.5
EW60P10 EW60N10 EW60R10 0-60 0-10 RG-8U 3.5


Outline Drawing