FL Series
1500 Watt Regulated
High Voltage
DC Power Supplies |

PDF Print Version
HTML Print Version
|
 |
| Models from 0 to
750V through 0 to 1500 V, 1.75” H x 19” W x 20” D, 15 lbs. |
|
| The FL Series are fully
compliant with the Following European Directives:
EN61000-3-2, Line Harmonics
EN61010/ IEC1010, Safety
EN61000-6-4, Conducted and Radiated Emissions
EN61000-6-2:2005, Conducted and Radiated Immunity |
|
- 750 to 1500V
- 1.75" Panel
- CE Compliant
- RoHS Compliant
|
The 1500 watt FL Series breaks new ground in
regulated high voltage DC power supply technology. 1.5 KW in a 1U package is a
power density not typically seen in power supplies above 600V. The FL Series
provides this high power density up to an amazing 1.5 kV without the reliability
issues inherent in connecting multiple low voltage supplies in series to achieve
a higher voltage.
The FL Series offers the features you’ve come
to expect in a cutting-edge power supply. Some of the unique features are:
- Embedded microprocessor control with
RS232, RS485, and USB communications as a standard feature; full analog
remote capability is retained.
- A fully floating output isolated to 1500V
allows the user to select the polarity by choosing which side of the output
to connect to Ground.
- Field strappable parallel operation allows
the user to add additional units as required to increase the output power.
Sophisticated circuitry is designed to
withstand the most demanding applications with ease. Whether used in a
laboratory environment, industrial process such as plasma coating or beam
steering, the FL Series design benefits from our 30 plus years of application
engineering experience. The finished result of our efforts is a full-featured
power supply with conservative design, long life, and uncompromising
reliability.
Compliance with RoHS and CE international
standards allows the user to integrate the FL Series into products as an
approved component, thereby reducing the burden placed on your Engineering and
Compliance departments as opposed to using non-approved items. Please take a few
minutes and read on, we have only touched the surface of FL Series’ broad range
of capabilities.
Features
Floating Output. Either output
terminal may be grounded for operation as a positive or negative supply.
Embedded Microcontroller control.
Front panel digital encoders provide high resolution local adjustment of voltage
and current program. Integral RS-232, RS-485, and USB communications
provide remote control program and monitor with 12 bit accuracy.
Remote Analog Interface. User
selectable 0-5V or 0-10V analog programming and monitors.
Field Strappable Parallel Operation.
Up to 4 identical supplies may be operated in parallel with user configurable
master and active current sharing.
Zero Space Stacking.
1U rack mount supplies may be stacked with no space required between supplies.
Low Ripple.
Ripple is less than 0.05% RMS of rated voltage at full load up to 1 MHz. Total
ripple and noise is less 0.2% p-p of rated voltage up to 20 MHz.
Constant
Voltage/Constant Current Operation.
Automatic crossover from constant-voltage to constant-current regulation
provides protection against overloads, arcs, and short circuits.
Constant
Current/Current Trip.
A rear panel switch allows selection of either current mode.
Cooling.
Fan speed control is adjusted automatically as a function of operating
temperature. This reduces noise and extends fan life.
Warranty.
Standard power supplies are warranted for three years; OEM and modified power
supplies are warranted for one year. A formal warranty statement is available.
Specifications
Input:
90-264 VAC continuous, single-phase, 48-63Hz. The RMS input current at rated
power is less than 20 A @ 100 VRMS input and less than 11 A @200 VRMS input.
Output power is linearly de-rated from 100% to 90% between 100V and 90V input.
Inrush Current:
30 A max. peak inrush current, 90 to 264 VAC.
Efficiency:
84% typical at full load.
Power factor: 0.99 typical at full load.
Output:
Continuous, stable adjustment, from 0 to rated voltage or current by panel
mounted optical rotary encoder or by external, user selectable, 0 to +5V or 0 to
+10V signals. Voltage accuracy is 0.5% of setting + 0.2% of rated. Current
accuracy is 0.5% of setting + 0.2% of rated. Voltage and Current programming
ranges are selected by switches that are accessible from the rear panel.
Optical rotary encoder resolution: 1V and 1mA with "Fine Adjustment" mode
selected. 10 V and 10 mA with "Coarse Adjustment" mode (default).
Static Line Regulation:
Better than 0.01% of the Voltage and Current Ratings for 100-132 VAC or 180-264
VAC line variations, under constant load.
Static Load
Regulation:
Max. 0.05% of Rating for full load to no load variation.
Current Regulation:
Better than 0.02% of the rating + 4mA, for short circuit to rated output voltage
variation, at any load condition.
Dynamic Voltage
Regulation:
Typical deviation is 1.5% of rating with recovery to within .5% of rating in
2ms for load transients from 10% to 100% and 100% to 10%.
Ripple and noise (p-p,
up to 20 MHz):
Max. 0.2% of rated voltage.
Ripple (RMS, 10 Hz -
1 MHz): Max.
0.05% of rated voltage. The ripple and noise are measured at the output
connectors of the supply.
Temperature
Coefficient:
Max. 100 ppm per deg C following 30 minute warm up.
Stability:
Max. 0.05% of rated over 8 hours time interval, following 30 minute warm up.
Voltage Rise Time
Constant:
Typical 45 ms using any of the HV ON, HV enable, local, the remote serial or the
remote analog control.
Voltage Decay Time
Constant:
Typical 45 ms time constant for an equivalent resistive load at the output of
33% of the rated full load.
Polarity:
Output is floating and either (DC+) or (DC -) can be connected to chassis ground
for reversible polarity. The sum of the output voltage and the float voltage
should not exceed 1500 VDC.
Field Strappable
Parallel operation:
Up to 4 identical units can be connected in parallel providing active current
sharing with user configurable master - slave configuration.
Analog Voltage Monitor:
User selectable 0 to +5 V or 0 to +10 V, equals 0 to rated, with an accuracy of
.5% of reading + 0.2% of rated.
Analog Current
Monitor: User
selectable 0 to +5 V or 0 to +10 V, equals 0 to Rated, with an accuracy of .5%
of reading + 0.2% of rated.
RS232/485 Programming
and Monitor Accuracy:
Resolution:
0.025% of full scale for both the voltage and the current channels.
Remote setting
accuracy:
Voltage setting accuracy is better than 0.5% of setting + 0.2% of rated.
Current setting accuracy is better than 0.5% of setting + 0.2% of rated.
Remote reading
accuracy:
Voltage reading accuracy is 0.5% of reading + 0.2% of rated. Current
reading accuracy is 0.5% of reading + 0.2% of rated.
Protection:
Automatic current regulation protects against all overloads, including arcs and
short circuits. Thermal switches and temperature rise sensing fans protect
against thermal overload. Fuses, surge-limiting resistors, and low energy
components provide ultimate protection.
External Interlock:
Open = off, closed = on.
Front Panel Elements.
Output Voltage
Display: 4
Digits / 0.2% ± 1 count accuracy; 1 V resolution.
Output Current
Display: 4
Digits / 0.2% ± 1 count accuracy; 1 mA resolution.
Indicators:
Current Mode, Voltage Mode, Fault, Fine Adjustment, Preset, Remote/Local, HV
On.
AC Power:
Rocker switch with integral indicator.
Switches
(momentary):
Baud Rate, Address, Remote/Local, Fine Adjust, Preset, HV On, UVP Adjust,
OVP Adjust.
Rotary Encoders:
Voltage Adjust, Current Adjust.
Rear Panel Elements:
AC power entry terminal strip, AC On indicator, ground stud, HV output
connectors, multifunction DIP switch, Analog Interface Connector, RS-232/RS485
connectors, and USB connectors.
Control and Status
Signals (J1)
Implemented with TTL compatible, 0 to 5.5 V CMOS, positive logic circuitry.
LOC/REM Status:
LOW/HIGH indicates Local / Remote Control Mode.
ENABLE/REMA
Input:
Active in Remote Analog control as HV enable. LOW / HIGH for HV OFF / ON.
Logic can be reversed by selected switch on the rear panel.
V/I MODE Status:
HIGH / LOW indicates that output is in Voltage/ Current Mode.
LOC/REMA Enable:
LOW /HIGH sets the power supply in Local / Remote analog mode.
FAULT Status:
Active HIGH, indicates a fault condition. Logic can be reversed by selected
switch on the rear panel. The continuously monitored faults are: Input
Undervoltage, Over Temperature, Over Voltage, Over Current, Interlock and
(optional) Arc Fault.
HV Status:
LOW /HIGH indicates that HV output is OFF/ ON.
Environmental:
Operating
Temperature:
0 to +40 deg C, full load.
Operating
Humidity: <
90% RH (no condensation).
Storage
Temperature:
-20 to +70 deg C.
Storage
Humidity:
< 95 % RH (no condensation).
Altitude:
For operation
above 6500 ft and up to 10,000 ft. MAX, de-rate the output current linearly
from 100% to 80% of rated.
Cooling:
Forced air cooling with internal fans.
Dimensions (W X H X D):
19" X 1.72" X 20". Refer to the outline drawing.
Weight:
15 lbs (6.9 kg)
AC Input Connector:
Screw Terminal Block, Phoenix P/N 1703034 and Housing for cable strain relief.
Output Connectors:
2 high voltage, self locking , Alden connectors, V121B. Mating connectors,
V131B, attached to 10 ft of 22AWG high voltage wire are provided. Steel housings
provides safety protection for both the AC input and the HV connectors.
Withstand Voltage and Insulation (HI-POT):
Input to Output:
2500 VAC
RMS,
Input to Ground:
2000 VAC RMS,
Output to Ground:
2500 VAC RMS,
Input to SELV:
2000 VAC RMS,
Output to SELV:
2500 VAC RMS,
Customer Serial
Interface to FL GND:
1000 VAC RMS.
Options
| Symbol |
Description |
| SS |
Slow Start Ramp:
Specify standard times of 5, 10, 15, 20, or 30 seconds, ±20%. |
| AQ |
Arc Quench: An arc
quench feature provides sensing of each load arc and quickly inhibits the HV
output for approximately 20 ms after each arc. |
| AC |
Arc Count: Internal
circuitry senses the number of arcs caused by external load discharges. If
the rate of consecutive arcs exceeds approximately 2 arcs per second for at
least five arcs, the supply will turn off for approximately 2.5 seconds to
allow clearance of the fault. After this period, the supply will return
automatically to the programmed output voltage value with the voltage rise
time constant indicated. If the load fault still exists, the above cycle
will be repeated |
Models
Click on the model number below to request a quote and
for complete ordering part number.
| Model |
Output
Voltage |
Output
Current |
Stored
Energy |
Ripple and
Noise MAX (P-P) |
|
FL0750F2.0 |
0-750V |
0-2.0A
| 2.80J |
1.5V |
|
FL1000F1.5 |
0-1000V |
0-1.5A |
5.00J |
2.0V |
|
FL1250F1.2 |
0-1250V |
0-1.2A |
6.25J |
2.5V |
|
FL1500F1.0 |
0-1500V |
0-1.0A |
6.75J |
3.0V |
Outline Drawing

|