KL Series
3000 Watt Regulated
High Voltage
DC Power Supplies |

PDF Print Version
HTML Print Version
|
 |
Models from 0 to 1kV through 0 to 30kV, 3kW, PF>0.99.
Seven inches high x 19 wide x 20 deep. Total weight less than 50 pounds. |
|
| Fully compliant with the European harmonized
EMI directive, EN50082-2, and with the low voltage (safety) directive, 73/23/EEC. |
|
- Power Factor Corrected to >0.99
- Well Within EN61000-3-2 Specifications
- High Speed Dynamic Voltage Regulation
- Single-phase, 198-264 V Input, 3500 VA
|
The KL Series...sophisticated 3kW High Voltage DC power supplies. The KL offers models with a voltage range from 1-30kV while providing low ripple and noise, high-speed dynamic voltage regulation, and active power factor correction while only requiring a single-phase input voltage.
As with other DC power supply products from Glassman, the KL series features notable technology benefits including 1: Glassman’s proprietary air-insulation technology—where air is used as the primary dielectric medium, in comparison to competitive models that utilize silicon rubber, epoxy or oil. Air offers distinct advantages from both a long-term reliability standpoint and serviceability over the extended life of the product. 2. Robust circuits that handle arcing and short circuit conditions in dynamic environments that will not compromise reliability or long lasting performance. This feature makes the KL ideal for use with Web coaters , E-Gun/Ion sources and Accelerator applications to name a few. The KL can also be used as a reliable, general laboratory high voltage power supply.
The KL series is CE Mark certified and can be utilized with the RS-232 digital interface option, which is now available for all Glassman standard models. Glassman also offers a comprehensive three-year warranty and support from its staff of application engineers.
Features
Power-factor Corrected. Active correction circuitry achieves a full
load power factor of better than 0.99.
Low Stored Energy. Most models exhibit less than 4 joules of stored
energy.
High Speed Dynamic Voltage Regulation. Rapid responding control circuits
provide a typical response of less than 500 µs to load transients.
Single-phase Input. Full 3kW output from a single-phase, 198-264 V,
48-63 Hz input, 3500 VA maximum.
Pulse-Width Modulation. Off-the-line pulse-width modulation provides
high efficiency, a fixed switching frequency, and a reduced parts count for improved reliability.
Air insulated. The KL Series features "air" as the primary
dielectric medium. Assemblies use no oil or encapsulation that could impede serviceability or increase weight.
Constant Voltage/Constant Current Operation. Automatic crossover from
constant-voltage to constant-current regulation provides protection against overloads, arcs, and short circuits.
Low Ripple. Ripple is less than 0.02% of rated voltage at full load.
Tight Regulation. Voltage regulation is better than 0.005% for allowable
line variations and 0.01% for load variations. Current regulation is better than 0.05% from short circuit to
rated voltage.
Front Panel Controls (Digital and Optional Analog Versions.) Separate
10-turn controls with locking vernier dials are used to set voltage and current levels. A high voltage enable
(on) switch, a high voltage disable (off) switch, and an AC power on/off switch complete the panel controls.
L.E.D.'s indicate when high voltage is on, the output polarity, and whether the supply is operating in a voltage
or current regulating mode. For the blank panel version, only a power on/off switch is provided on the panel.
Small Size and Weight. KL Series power supplies occupy only 7 inches
of panel height. Net weight is less than 50 pounds.
Warranty. Standard power supplies are warranted for three years; OEM
and modified power supplies are warranted for one year. A formal warranty statement is available.
Specifications
(From 5% to 100% rated voltage. All units operate down to zero output with
very slight degradation of performance.)
Input: 198-264 V RMS, single-phase, 48-63 Hz, 3500 VA maximum, <16A
at 220 V. A 3-position terminal block with protective cover is provided.
Efficiency: Typically 87% at full load. Power factor >0.99.
Output: Continuous, stable adjustment,
from 0 to rated voltage or current by panel mounted 10-turn potentiometers with
0.05% resolution, or by external 0 to 10V signals is provided. Voltage accuracy
is 0.5% of setting + 0.2% of rated. Repeatability is < 0.1% of rated.
Stored Energy: See Models chart.
Static Voltage Regulation: Better than 0.005% for specified line variations
and 0.01% + 0.2 volts per ampere for load variations.
Dynamic Voltage Regulation: For load transients from 10% to 100% and 100%
to 10%, typical deviation is 2% of output voltage with recovery to within 1% in 500 µs and to 0.1% in 1ms.
Ripple: <0.02% of rated voltage + 500 mV RMS.
Current Regulation: Better than 0.1%
from short circuit to rated voltage at any load condition.
Voltage Monitor: 0 to + 10 V equivalent to 0 to rated voltage. Accuracy,
0.5% reading +0.5% rated.
Current Monitor: 0 to + 10 V equivalent to 0 to rated current. Accuracy,
1% reading +0.05% rated for single polarity, 1% reading + 0.1% rated for reversible polarity.
Stability: 0.01% per hour after 1/2 hour warmup, 0.05% per 8 hours.
Voltage Rise/Decay Time Constant: 50 ms typical with a 10% resistive
load using either HV on/off or remote programming control.
Temperature Coefficient: 0.01% per degree C.
Ambient Temperature: -20 to +40 degree C, operating; -40 to +85 degree C,
storage.
Polarity: Available with either positive, negative, or reversible polarity
with respect to chassis ground.
Protection: Automatic current regulation protects against all overloads,
including arcs and shorts. Fuses, surge-limiting resistors, and low energy components provide ultimate protection.
Remote Controls: Terminal block is provided for all remote functions
including common, +10V reference, interlock, voltage and current program/monitor, HV Enable/Disable, ground, and
local control.
External Interlock: Open off, closed on. Normally latching except for
blank panel version where it is non-latching.
HV Enable/Disable: 0-1.5 V off. 2.5-15 V on.
Options
| Symbol |
Description |
| 200 |
200 V ± 10% input, 48-63 Hz. Derate currents by 10%, maximum 2700 W. |
| AM |
Dual analog panel meters. |
| NC |
Blank front panel, power switch only. |
| CT |
Current trip. Power supply trips off when the load current reaches the programmed level. This option has a rear panel switch that selects either "trip" operation or current limiting. |
| ZR |
Zero start interlock. Voltage control, local or remote, must be at zero before accepting an enable signal. |
| SS |
Slow start ramp. Specify standard times of 1,2,3,5,10,15,20, or 30 s ± 20% |
| 5VC |
0-5 V voltage and current program/monitor. Other options are available. Please consult factory. |
| GE9 |
RS-232 control and monitor. |
Models
Click on the model number below to request a quote and
for complete ordering part number.
Outline Drawing

|