Glassman High Voltage is a leading designer and manufacturer of High Voltage power supplies/DC power supplies for the High Voltage and Vacuum Process equipment market segments. A Glassman DC power supply can range in output from 15W-50kW with output voltages operating down to 50V thru 400kV.  A High Voltage power supply of this type can be offered in modular or Rack-mount configuration as well as special packaging to meet customer-specific mechanical requirements. Most Glassman DC power supplies are offered utilizing proprietary Air Insulation dielectric technology. Air poses numerous reliability and serviceability benefits in comparison to competing solid and liquid dielectric technologies.
home
about us
products
contact us
technology
opportunities
site map
search
request info
warranty

Glassman HV Catalog

request quote

request short
form catalog

download our
standard catalog

Recent Glassman Ads

 Product Locator:    

LK Series
3 kW Regulated
High Voltage
DC Power Supplies


PDF Print Version

HTML Print Version

LK Series HV Power Supply
Models from 0 to 40 kV through 0 to 100 kV, 8.75" H x 24.0" D, 55 lbs.
The LK Series are fully compliant with the European Harmonized EMI Directive EN50082-2 and with the European Low Voltage (Safety) Directive, 73/23/EEC.
  • 40 kV to 100 kV
  • Rack Mount
  • CE Compliant
  • Power Factor Corrected to > .995
  • Harmonics Well Below EN61000-3-2
  • Semi S2-93 Compliant

The LK family of power supplies are sophisticated, 3 kW, high voltage power supplies with low ripple and noise. They are air insulated, fast response units, with tight regulation. They are designed to meet the growing demands from both users and electric utilities for switching supplies with excellent input power factors that draw harmonic currents well below those specified in EN61000-3-2.
Features Specifications Options Models Outline


Features

Power Factor Corrected. Active correction circuitry achieves an input line current harmonic content well below the maximum specified in EN61000-3-2.

Arc Quench. The HV output is inhibited for a short period after each load arc to help extinguish the arc.

Arc Sensing. Internal circuitry constantly senses and integrates arcs that occur over a given time. In the event a system or load arcing problem develops and exceeds factory-set parameters, the power supply will cycle off in an attempt to clear the fault and then automatically restart after a preset "off dwell time".

Pulse-Width Modulation. Off-the-line pulse-width modulation provides high efficiency and a reduced parts count for improved reliability.

Low Ripple. Ripple is less than 0.025% RMS of rated voltage at full load.

Air Insulated. The LK Series features "air" as the primary dielectric medium. No oil or encapsulation is used to impede serviceability or increase weight.

Constant Voltage/Constant Current Operation. Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs, and short circuits.

Constant Current/Current Trip. A rear panel switch allows selection of either current mode.

Redundant Thermal Overload Protection. Thermostats and fan RPM sensing shut down the power supply due to over temperature or reduced fan speeds.

Tight Regulation. Voltage regulation is better than 0.005% for allowable line variations and 0.01% for allowable load variations. Current regulation is better than 0.1% from short circuit to rated voltage.

Warranty. Standard power supplies are warranted for three years; OEM and modified power supplies are warranted for one year. A formal warranty statement is available.


Specifications

(Specifications apply from 5% to 100% rated voltage. Operation is guaranteed down to zero voltage with a slight degradation of performance.)

Input: 198 - 264 V RMS, single-phase, 48-63 Hz, 3500 VA maximum at full load. Less than 16 A at 220 VAC. A three position rear terminal block with protective cover is provided.

Efficiency: Typically greater than 85% at full load. Power factor >0.995.

Output: Continuous, stable, adjustment from 0 to rated voltage or current by panel mounted 10-turn potentiometers with 0.05% resolution, or by external 0 to 10 V signals is provided. Linearity is < 1% of rated. Accuracy is 0.2% of rated + 0.5% of setting for voltage program and 0.2% of rated +1% of setting for current program.

Static Voltage Regulation: Better than ±0.005% for specified line variations and 0.01% for no load to full load variations.

Dynamic Voltage Regulation: For load transients from 10% to 99% and 99% to 10%, typical deviation is less than 2% of rated output voltage with recovery to within 1% in 500 µs and recovery to within 0.1% in 1 ms.

Ripple: Better than 0.025% RMS of rated voltage at full load.

Current Regulation: When in current regulation mode, better than 0.1% from short circuit to rated voltage at any load condition. When in current trip mode the HV output will disable and latch off when the load current reaches the programmed current level. Reset is accomplished by either cycling the AC power or HV ON/OFF buttons, or by toggling the HV enable signal. A switch located on the rear panel allows the selection of current limit modes: constant current, or current trip.

Voltage Monitor: 0 to +10 V equivalent to 0 to rated voltage. Accuracy, 0.5% reading + 0.2% rated. Impedance is 10 K Ohm.

Current Monitor: 0 to +10 V equivalent to 0 to rated current. Accuracy, 1% reading + 0.2% rated. Impedance is 10 K Ohm.

Stability: 0.01% per hour after 1/2 hour warm-up, 0.05% per 8 hours.

Voltage Rise/Decay Time Constant: 200 ms typical with a 7% resistive load using either HV enable or remote programming control.

Temperature Coefficient: 0.01%/ºC.

Ambient Temperature: -20 to +40ºC, operating; -40 to +85ºC, storage.

Protection: Automatic current regulation protects against all overloads, including arcs and short circuits. Thermal switches and RPM sensing fans protect against thermal overload. Fuses, surge-limiting resistors, and low energy components provide ultimate protection.

Arc Quench: An arc quench feature provides sensing of each load arc and quickly inhibits the HV output for approximately 20 ms after each arc.

Arc Sensing: Internal circuitry senses the number of arcs caused by external load discharges. If the rate of consecutive arcs exceeds approximately one arc per second for five arcs, the supply will turn off for approximately 5 seconds to allow clearance of the fault. After this period the supply will automatically return to the programmed kV value with the rise time constant indicated. If the load fault still exists, the above cycle will repeat.

External Interlock: Open = off, closed = on. Normally latching except for blank front panel version where it is non-latching.

Front Panel Elements. The front panel contains all local control functions. These control functions are: AC power on/off switch and pilot light, separate 10-turn controls with locking vernier dials used to set voltage and current levels, HIGH VOLTAGE ON switch, and HIGH VOLTAGE OFF/RESET switch. LED's indicate when high voltage is on, output polarity, and whether the supply is operating in a voltage or current regulating mode. Output levels are indicated by voltage and current digital meters.

Rear Panel Elements. AC power entry terminal strip, fuses, power on indicator, ground stud, HV output connector, current limit/current trip switch, and remote interface terminal strip.

The signals provided on the remote interface terminal strip are as follows:

  • Inputs: Safety interlock, output voltage and current program signals, and high voltage enable.
  • Outputs: Output voltage and current monitor signals, and a +10 V reference source.

Signal common and ground reference terminals are also provided.

Remote HV Enable/Disable: 0 - 1.5 V = OFF, 2.5 - 15 V = ON.

Accessories: Detachable, 8 foot, shielded Dielectric Sciences DS2124 high voltage coaxial cable provided.

Weight: 55 pounds.


Options

Symbol Description
200 180 to 220 VRMS input, 48-63 Hz, derate output current by 10%.
AM Dual analog panel meters.
NC Blank front panel, power switch only.
ZR Zero start interlock. Voltage control, local or remote, must be at zero before HV will enable.
SS Slow start ramp. Specify standard times of 1, 2, 3, 5, 10, 15, 20 or 30 s ± 20%
5VC 0-5 V voltage and current program/monitor.
HVS High voltage status and fault indicators. Status is form "C" relay contacts that activate when HV is enabled. Fault is form "C" contacts that activate when an internal fault occurs. Contacts are rated for 24VDC at 1A maximum.
GE9 RS-232 control and monitor.
Please consult factory for special requirements.


Models

Click on the model number below to request a quote and for complete ordering part number.

Positive
Polarity
Negative
Polarity
Reversible
Polarity
Output
Voltage
(kV)
Output
Current
(mA)
Stored
Energy
(Joules)
LK40P75 LK40N75 LK40R75 0 - 40 0 - 75 8
LK50P60 LK50N60 LK50R60 0 - 50 0 - 60 10
LK60P50 LK60N50 LK60R50 0 - 60 0 - 50 12
LK70P43 LK70N43 LK70R43 0 - 70 0 - 43 14
LK80P37 LK80N37 LK80R37 0 - 80 0 - 38 16
LK100P30 LK100N30 LK100R30 0 - 100 0 - 30 20