LQ Series
10 kW - 50 kW Regulated
High Voltage
DC Power Supplies
|

PDF Print Version
HTML Print Version
|
 |
| Models
from 0 to1 kV through 0 to 12 kV, 8.75” H x 19” W x 24.0” D, 60 lbs. |
|
| The LQ Series are fully compliant with the European Harmonized
EMI Directive EN50082-2 and with the European Low Voltage (Safety) Directive, 73/23/EEC. |
|
- 1 kV to 12 kV
- Rack Mount
- CE Compliant
- Semi S2-93 Compliant
|
Glassman’s LQ family of power supplies are sophisticated, 10 kW, high voltage power supplies with low ripple and noise. They are air insulated, fast response units, with tight regulation.
The “low-height” LQ series offers models from 1-12KV that provides a fully adjustable output voltage and current range, while providing low output ripple and noise, proprietary Arc Quench and Arc Count circuitry, low stored energy and reduced weight in an 8.75 inch height (5U) rack-mount enclosure.
The LQ series can be utilized in a host of OEM and Research applications including Electron-beam processing, Physical Vapor Deposition, Microwave processing utilizing Magnetron tubes and Particle accelerator research.
The LQ is available in Master/Slave configurations up to 50kW (1 Master/4 Slave units). Please consult factory for additional details.
Features
Arc Quench. The HV output is inhibited for a short period
after each load arc to help extinguish the arc.
Arc Count. Internal circuitry constantly senses and integrates
arcs that occur over a given time. In the event a system or load arcing problem develops and exceeds
factory-set parameters, the power supply will cycle off in an attempt to clear the fault and then
automatically restart after a preset “off dwell time.”
Pulse-Width Modulation. Off-the-line pulse-width modulation
provides high efficiency and a reduced parts count for improved reliability.
Low Ripple. Ripple is less than 0.1% RMS of rated voltage at
full load.
Air Insulated. The LQ Series features “air” as the primary
dielectric medium. No oil or encapsulation is used to impede serviceability or increase weight.
Constant Voltage/Constant Current Operation. Automatic crossover
from constant-voltage to constant-current regulation provides protection against overloads, arcs, and
short circuits.
Constant Current/Current Trip. A rear panel switch allows
selection of either current mode.
Redundant Thermal Overload Protection. Thermostats and fan RPM
sensing shut down the power supply due to over temperature or reduced fan speeds.
Tight Regulation. Voltage regulation is better than 0.05% for
allowable line variations and 0.05% for allowable load variations. Current regulation is better than 0.5% from short circuit to rated voltage.
Warranty. Standard power supplies are warranted for three years;
OEM and modified power supplies are warranted for one year. A formal warranty statement is available.
Specifications
(Specifications apply from 5% to 100% rated voltage. Operation is guaranteed
down to zero voltage with a slight degradation of performance.)
Input: 187 - 228 V RMS, three-phase, 48-63 Hz, 14.5 kVA maximum at full
load (less than 45 A/phase). Inrush current is less than 150 A. A five position
terminal strip is provided for AC line connection. Mains service must be protected with fuses or circuit breakers
with a maximum rating of 125A and a minimum interrupting capacity of 50,000 A.
Efficiency: Typically greater than 85% at full load.
Output: Continuous, stable adjustment from 0 to rated voltage/current by
means of panel-mounted 10-turn potentiometers (0.05% resolution), or external 0 to +10 V signals. Repeatability
better than 0.1% of setting.
Voltage programming accuracy: 0.5% of setting + 0.2% of rated output.
Resolution is a function of the programming method used.
Current programming accuracy: 1% of setting plus
1% of rated
output.
Line Regulation: < +/- 0.05% of rated output for a +/-10% input line
variation.
Load Regulation: < +/- 0.05% of rated output for a no load to full
load change.
Ripple: < 0.1% +1V RMS of rated output voltage.
Current Regulation: Better than 0.5% from short circuit to rated voltage
at any load condition.
Voltage Monitor: 0 to +10 V equivalent to 0 to rated voltage. Accuracy,
0.5% of reading + 0.2% of rating. Output impedance is 10 K Ohm.
Current Monitor: 0 to +10 V equivalent to 0 to rated current. Accuracy:
1% of setting plus 1% of rated output. Output impedance is 10 K ohm.
Stability: 0.01% per hour after 1/2 hour warm-up, 0.05% per 8 hours.
Voltage Rise Time Constant: 50 ms typical, using either HV enable or
remote programming control.
Temperature Coefficient: 0.01%/° C.
Ambient Temperature: -20 to +40° C, operating; -40 to +85° C, storage.
Polarity: Available with either positive or negative polarity.
Protection: Automatic current regulation protects against all overloads,
including arcs and short circuits. Thermal switches and rpm sensing fans protect against thermal overload.
Circuit breaker, fuses, surge-limiting resistors, and low energy components provide ultimate protection.
Arc Quench: An arc quench feature
provides sensing of each load arc and
quickly inhibits the HV output for approximately 20 ms after each arc.
Arc Count: Internal circuitry senses the number of arcs caused by
external load discharges. If the rate of consecutive arcs exceeds approximately one arc per second for five
arcs, the supply will turn off for approximately five seconds to allow clearance of the fault. After this
period, the supply will return automatically to the programmed output voltage value with the voltage rise time
constant indicated. If the load fault still exists, the above cycle will be repeated.
Current Limit: In current limit mode the power supply will regulate the
load current at the programmed current level with automatic crossover between voltage and current regulating
modes.
Current Trip: A switch located on the rear of the control panel assembly
allows the selection of current limit or current trip operation. When the switch is set to current trip mode,
the HV output will disable and latch off when the load current reaches the programmed current level. Reset is
accomplished by either cycling the AC power, toggling the HV enable signal, or by pushing the HV off/reset and
then the HV on switches.
Front Panel Elements: The front panel contains all local control
functions and indicators. These are: AC power on/off circuit breaker and indicator light, separate 10-turn
controls with locking vernier dials used to set voltage and current levels, high voltage on switch, and high
voltage off/reset switch. LED's indicate: when high voltage is on, output polarity, interlock, fault status,
and whether the supply is operating in a voltage or current regulating mode. Output levels are indicated by
voltage and current digital meters.
Rear Panel Elements: The rear panel contains the AC mains input
connections
with safety cover, AC power indicator, HV output, ¼-20 ground return stud, CL/CT switch, 25 pin "D" interface
connector, and a 12 position terminal strip. The terminal strip provides local/remote signal selection, interlock,
and remote HV ON/OFF functions.
Remote Control Interface: All LQ family power supplies provide a
standard user's remote interface.
The signals provided are:
Inputs: Safety interlock, output voltage and current program signals,
high voltage enable and connections for remote HV on and off push buttons
Outputs: Output voltage and current monitor signals, HV enable status,
I/V regulation mode status, fault status, and a +10 V reference source. Signal common and ground reference
terminals are also provided.
Optional Analog Interfaces:
Differentially coupled program and monitor signals.
4-20mA program and monitor signals.
RS232 computer interface (external add on assembly).
External Interlock: Open = off, closed = on. Normally latching except
for "NC" option supplies where it is non-latching. The interlock indicator LED is lit when the interlock
is open.
HV Enable:
Remote Mode: 0 - 1.5 V = OFF, 2.5 - 15 V = ON.
Local Mode: The HV output is permanently enabled.
HV Status, Fault and I/V Regulation Status: Each are a set of form
"C" relay contacts.
Accessories: Detachable, 8 foot, shielded high voltage coaxial cable
is provided. A 25 pin D-subminiature connector for customer or computer interface is provided.
Regulatory: The system will meet the European conducted emission
standards as specified in EN50082-2 per EN55011 and the European Low Voltage Directive, 73/23/EEC.
Size: 8.75"H X 19"W X 24"D rack mounted chassis. Forced air cooling
is employed.
Options
| Symbol |
Description |
| NC |
Blank front
panel, AC power breaker/switch and indicator only. |
| ZR |
Zero start
interlock. Voltage control, local or remote, must be at zero before HV
will enable. |
| SS |
Slow start ramp.
Specify standard times of 5, 10, 15, 20 or 30 Sec, ±20%. |
| 5VC |
0-5 V voltage and
current program/monitor. |
| GE9 |
RS-232 control and monitor. |
| Please consult factory for special requirements. |
Models
Click on the model number below to request a quote and
for complete ordering part number.
Outline Drawing

|