Glassman High Voltage is a leading designer and manufacturer of High Voltage power supplies/DC power supplies for the High Voltage and Vacuum Process equipment market segments. A Glassman DC power supply can range in output from 15W-50kW with output voltages operating down to 50V thru 400kV.  A High Voltage power supply of this type can be offered in modular or Rack-mount configuration as well as special packaging to meet customer-specific mechanical requirements. Most Glassman DC power supplies are offered utilizing proprietary Air Insulation dielectric technology. Air poses numerous reliability and serviceability benefits in comparison to competing solid and liquid dielectric technologies.
home
about us
products
contact us
technology
opportunities
site map
search
request info
warranty

Glassman HV Catalog

request quote

request short
form catalog

download our
standard catalog

Recent Glassman Ads

 Product Locator:    

LX Series
Extended Current*
1000 Watt Regulated
High Voltage
DC Power Supplies


PDF Print Version

HTML Print Version

LX Series HV Power Supply
Models from 0 to 1kV through 0 to 150kV.
Fully compliant with the European harmonized EMI directive, EN50082-2, and with the low voltage (safety) directive, 73/23/EEC.
  • Up To 150kV
  • 8.75 Inch Panel Height
  • Laboratory Performance
  • Enhanced Features

The LX Series are 1000 watt regulated high voltage DC power supplies with an important difference ... maximum current ratings are equivalent to a 2000W supply! This maximum current, which is available for all output voltages up to 50% of rated voltage, should be of significant interest for many applications. The LX is offered with dual analog voltage and current meters or, optionally, with dual digital meters, or a blank panel for OEM/systems applications.
Features Specifications Options Models Outline


Features

*Extended Current. LX models have maximum current ratings that are equivalent to a 2000W supply. These currents are available up to 50% of rated output voltage. Above this point, current is derated to maintain a constant 1000 W maximum output.

Pulse-Width Modulation. Off-the-line pulse-width modulation provides high efficiency and a reduced parts count for improved reliability.

Air Insulated. The LX Series features "air" as the primary dielectric medium. No oil or encapsulation is used to impede serviceability or increase weight.

Constant Voltage/Constant Current Operation. Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs, and short circuits.

Low Ripple. Ripple is less than 0.03% of rated voltage at full load.

Tight Regulation. Voltage regulation is better than 0.005% for allowable line and load variations. Current regulation is better than 0.05% from short circuit to rated voltage.

Front Panel Controls (Analog and Digital Versions.) Separate 10-turn controls with locking vernier dials are used to set voltage and current levels. A high voltage enable switch and an AC power on/off switch complete the panel controls. L.E.D.'s indicate when high voltage is on, the output polarity, and whether the supply is operating in a voltage or current regulating mode. For the blank panel version, only a power on/off switch is provided on the panel.

Small Size and Weight. LX Series power supplies occupy only 8.75 inches of panel height. Net weight is less than 47 pounds.

Warranty. Standard power supplies are warranted for three years; OEM and modified power supplies are warranted for one year. A formal warranty statement is available.


Specifications

(From 5 to 100% of rated voltage. All units operate down to zero output with very slight degradation of performance.)

Input: 102-132V RMS, single-phase, 48-63Hz, <20 A. A 3-position terminal block with protective cover is provided.

Efficiency: Typically 85% at full load.

Output: Continuous, stable adjustment, from 0 to rated voltage or current by panel mounted 10-turn potentiometers with 0.05% resolution, or by external 0 to 10V signals is provided. Linearity is <1% of rated. Accuracy is 1% of rated + 1% of setting. Repeatability is <0.1% of rated.

Stored Energy: 60kV: 15J; 125kV: 30J.

Voltage Regulation: Better than 0.005% for specified line variations and 0.005% + 1 mV/mA for load variations.

Ripple: <0.03% of rated voltage + 1V RMS at full load (0.1% for 150 kV).

Current Regulation: Better than 0.05% from short circuit to rated voltage at any load condition.

Voltage Monitor: 0 to +10V equivalent to 0 to rated voltage. Accuracy, 1% reading +1% rated.

Current Monitor: 0 to +10V equivalent to 0 to rated current. Accuracy, 1% reading + 0.1% rated for single polarity, 1% reading + 0.15% rated for reversible polarity.

Stability: 0.01% per hour after 1/2 hour warmup, 0.05% per 8 hours.

Voltage Rise/Decay Time Constant: 50 ms typical to 60kV (400 ms for higher voltages) with a 30% resistive load using either HV on/off or remote programming control.

Temperature Coefficient: 0.01% per degree C.

Ambient Temperature: -20 to +40 degrees C, operating; -40 to +85 degrees C, storage.

Polarity: Available with either positive, negative, or reversible polarity with respect to chassis ground.

Protection: Automatic current regulation protects against all overloads, including arcs and shorts. Fuses, surge-limiting resistors, and low energy components provide ultimate protection.

Accessory: Detachable 8-foot HV cable. See models chart for cable type.

Remote Controls: Terminal block is provided for all remote functions, including common, +10V reference, interlock, voltage and current program/monitor, HV Enable/Disable, ground, and local control.

External Interlock: Open off, closed on. Normally latching except for blank panel version where it is non-latching.

HV Enable/Disable: 0-1.5V off, 2.5-15V on.


Options

Symbol Description
100 100V ± 10% input, 48-63Hz. Derate currents by 20%, maximum 800W.
DM 3-1/2 digit LCD panel meters.
NC Blank front panel, power switch only.
CT Current trip. Power supply trips off when the load current reaches the programmed level. This option has a rear panel switch that selects either "trip" operation or current limiting.
ZR Zero start interlock. Voltage control, local or remote, must be at zero before accepting an enable signal.
SS Slow start ramp. Specify standard times of 1, 2, 3, 5, 10, 15, 20, or 30 s +/- 20%
5VC 0-5 V voltage and current program/monitor.
GE9 RS-232 control and monitor.


Models

Click on the model number below to request a quote and for complete ordering part number.

Positive
Polarity
Negative
Polarity
Reversible
Polarity
Output
Voltage
Output
Current
Output
Cable
Panel Height
Reversible
Polarity
Only
LX1R2000 0-1kV 0-2000mA RG-59 8.75 in.
LX1.5R1300 0-1.5kV 0-1300mA RG-59 8.75 in.
LX2R1000 0-2kV 0-1000mA RG-59 8.75 in.
LX3R660 0-3kV 0-660mA RG-59 8.75 in.
LX5R400 0-5kV 0-400mA RG-59 8.75 in.
LX6R330 0-6kV 0-330mA RG-58 8.75 in.
LX8P250 LX8N250 LX8R250 0-8kV 0-250mA RG-8U 8.75 in.
LX10P200 LX10N200 LX10R200 0-10kV 0-200mA RG-8U 8.75 in.
LX12P165 LX12N165 LX12R165 0-12kV 0-165mA RG-8U 8.75 in.
LX15P132 LX15N132 LX15R132 0-15kV 0-132mA RG-8U 8.75 in
LX20P100 LX20N100 LX20R100 0-20kV 0-100mA RG-8U 8.75 in.
LX30P66 LX30N66 LX30R66 0-30kV 0-66mA RG-8U 8.75 in.
LX40P50 LX40N50 LX40R50 0-40kV 0-50mA RG-8U 8.75 in.
LX50P40 LX50N40 LX50R40 0-50kV 0-40mA RG-8U 8.75 in.
LX60P33 LX60N33 LX60R33 0-60kV 0-33mA RG-8U 8.75 in.
LX80P25 LX80N25 LX80R25 0-80kV 0-25mA DS2124 8.75 in.
LX100P20 LX100N20 LX100R20 0-100kV 0-20mA DS 2124 8.75 in.
LX125P16 LX125N16 LX125R16 0-125kV 0-16mA DS 2121 8.75 in.
LX150P12 LX150N12 LX150R12 0-150kV 0-12mA DS 2121 8.75 in.

Note: Product of voltage and current automatically limited to 1000W maximum


Outline Drawing