MR Series
300 Watt Regulated
High Voltage
|

PDF Print Version
HTML Print Version
|
 |
| Models from 0-1 kV DC through 0-5 kV DC. |
|
| Fully compliant with the European harmonized
EMI directive, EN50082-2, and with the low voltage (safety) directive, 73/23/EEC. |
|
- Modules from 0 to 1 kV through 0 to 5 kV,
3.38" high x 7.25" wide x 16" deep (excluding interface connections).
- SHV connector version shown, Alden
connector available.
|
The MR Series...a sophisticated, medium power, high voltage power supply
designed to meet international safety approvals...is packaged as a space-saving module that avoids the
cost of expensive panels and displays. However, no compromises in performance and operating features
have been made. The result is a power supply that offers outstanding value for a wide range of
demanding applications.
Features
Air Insulated. Single printed circuit board construction for easy
access. Air insulation for serviceability and light weight.
Constant Voltage/Constant Current/ Current Trip Operation. Automatic
crossover from constant voltage regulation to current control for protection from overloads, arcs, and shorts. Current control is user configured for constant current regulation or current trip.
Low Ripple. Better than 0.02% RMS of rated voltage at full load.
Tight Regulation. Voltage regulation better than 0.005%, line or
load; current regulation better than 0.1% from short circuit to rated voltage.
Fast Transient Response. Less than 2 milliseconds for a 50% load
transient.
Local Control and Indicator. Ten-turn control for either voltage or
current. Power ON indicator.
Remote Interface Connections. Voltage or current local control,
voltage and current program and monitor terminals, current regulation/trip, TTL high voltage enable, safety
interlock terminals, +10 volt reference source, common, and chassis ground.
Small Size and Weight. 3.375" (85.4 mm) H x 7.25" (184.2)
W x 16.00" (406) D. Weight less than 11 pounds (5 kg.)
Output Connector and Cable. Choice of Alden connector with unshielded
silicone wire or SHV connector with RG-59 shielded cable.
Warranty. Standard power supplies are warranted for three years; OEM
and modified power supplies are warranted for one year. A formal warranty statement is available.
Specifications
(From 5% to 100% rated voltage. All units operate down to zero output with very slight
degradation of performance.)
Input: 103-132 V RMS, 48-63 Hz single phase, <6 A. Connector per IEC 320 with
mating line cord.
Efficiency: Typically 85% at full load.
Output: Continuous, stable adjustment, from 0 to rated voltage or current by panel
mounted 10-turn potentiometer with 0.05% resolution, or by external 0 to 10V signals is provided.
Linearity is <1% of rated. Accuracy is 0.25% of rated + 1% of setting. Repeatability
is <0.1% of rated.
Stored Energy: <0.5 joules.
Voltage Regulation: <0.005% for line variations. For load variations, add 1mV/mA.
Ripple: <0.02% RMS of rated voltage + 300 mV RMS.
Current Regulation: <0.1% of rated current from short circuit to rated voltage at
any set current.
Voltage Monitor: 0 to + 10 V DC for zero to rated voltage. Accuracy, 1% of reading
+0.25% of rated voltage.
Current Monitor: 0 to + 10 V DC for zero to rated current. Accuracy, 1% of reading
+0.05% of rated current.
Stability: 0.01% per hour after 1/2 hour warm-up, 0.05% per 8 hours.
Voltage Rise/Decay Time Constant: Typically 50 ms rise or decay time constant using
TTL on/off or remote voltage control with a minimum of 15% resistive load.
Temperature Coefficient: 0.01%/oC.
Ambient Temperature: -20 to +40oC operating, -40 to +85oC storage.
Polarity: Positive or negative with respect to chassis ground.
Protection: User-selected automatic current regulation or current trip protects
against all overloads, including arcs and short circuits. Fuses, surge-limiting resistors,
and low-energy components provide ultimate protection.
Accessories: Detachable 8-foot HV cable (see Models chart for choice of output
connector and cable type) and 6-foot detachable line cord provided.
Remote Connections: Common, +10V reference, interlock, current program, current
monitor, voltage program, voltage monitor, TTL HV enable, current regulation/trip, and
chassis ground.
External Interlock: Open off, closed on.
HV Enable/Disable: 0-1.5 V off, 2.5-15 V on.
Options
| Symbol |
Description |
| 100 |
100 V input, rated 90-110 V RMS, 48-63 Hz. |
| 200 |
200 V input, rated 180-220 V RMS, 48-63 Hz |
| 220 |
220 V input, rated 198-264 V RMS, 48-63 Hz. |
| 400 |
48-420 Hz, available on standard models and options 100, 200, and 220. |
| SS |
Slow start ramp, up to 30 seconds. Specify time. |
| 5VC |
0-5 V voltage and current program/monitor. |
Models
Click on the model number below to request a quote and
for complete ordering part number.
Models (Alden Connector)
Models (SHV Connector)
Outline Drawing

|