PG Series
500/1000 Watt Regulated
High Voltage
DC Power Supplies
PG-LR Series
250/500 Watt
Low Ripple
Regulated
High Voltage
DC Power Supplies
|

PDF Print Version
HTML Print Version
|
 |
| Models from 0 to 40 kV
through 0 to 100 kV, 8.75" H x 24.0" D, 55 lbs. |
|
|
|
- 100 kV to 400 kV
- Overload Protected
|
The PG Series is available in two configurations ... as a standard PG Series
supply or as an ultra-low ripple PG-LR Series for demanding applications, such as particle accelerators.
Shown is the dual-stack PG-LR Series with remote control unit. One stack serves as a high voltage
multiplier while the second stack provides an additional low-pass ripple filter and a shielded DC feedback
network. The standard PG Series is supplied with only the multiplier stack and remote control unit.
Features
Pulse-Width Modulation. Off-the-line pulse-width modulation provides high efficiency and a reduced parts count for improved reliability.
Air Insulation. Both PG series feature "air" as the primary dielectric medium. No oil or encapsulation is used that could impede serviceability or increase weight.
Constant Voltage/Constant Current Operation. Automatic crossover from constant-voltage to constant-current regulation serves to protect the supplies from overloads, arcs, and short circuits.
Tight Regulation. Voltage regulation is better than 0.005% for allowable line and load variations. Current regulation is better than 100 ľA from short circuit to rated voltage.
Ripple. Standard models better than 0.1% at full load. For the extremely low ripple values of the PG-LR series, see the models chart.
Warranty. Standard power supplies are warranted for three years; OEM and modified power supplies are warranted for one year. A formal warranty statement is available.
Specifications
(From 5% to 100% rated voltage. All units operate down to zero output with very
slight degradation of performance.)
Input: Series PG: 105-125 V RMS, single-phase, 48-63 Hz, <15 A. Series
PG-LR: 187-230 V RMS, 3-phase, 48-63 Hz, < 5 A per phase.
Efficiency: Typically 75% at full load.
Output: Continuous, stable adjustment, from 0 to rated voltage or current
by panel mounted 10-turn potentiometers with 0.05% resolution, or by external 0 to 10 V signals is provided.
Linearity is <1% of rated. Accuracy is 1% of rated +1% of setting. Repeatability is <0.1% of rated.
Voltage Regulation: Better than 0.005% + 1 V, line or load.
Ripple: Better than 0.1% of rated voltage at full load. Series PG-LR:
See models chart.
Current Regulation: Better than 100 ľA from short circuit to rated voltage
for any load condition; 0.005% + 1 ľA for line variations.
Voltage/Current Monitor: Zero to +10 V signal for zero to rated
voltage/current.
Stability: 0.01% +/1 V per hour after 1/2 hour warmup, 0.05% + 2 V per
8 hours.
Temperature Coefficient: 0.01% per degree C + 1 V.
Ambient Temperature: -20 to +60 degree C, operating; -40 to +85 degree C,
non-operating.
Polarity: Available with either positive, negative, or reversible polarity
with respect to chassis ground.
Protection: Automatic current regulation protects the power supply against
all overload conditions, including arcs and short circuits. Fuses, surge-limiting resistors, and low energy
components provide the ultimate protection.
External Interlock: Open off, closed on.
Options
| Symbol |
Description |
| 220 |
210-250 V input, 48-63 Hz (Series PG only) |
| 100 |
90-110 V input, 48-63 Hz (Series PG only) |
| 400Hz |
400 Hz input (Series PG only) |
| B |
Bi-polar
operation. Two supplies, with same voltage rating and opposite polarity, may be operated singlely or as a bi-polar pair. |
| CT |
Current
trip. Power supply trips off when the load current reaches the programmed level. This option has a rear panel switch that selects either "trip" operation or current limiting. |
| DM |
4-1/2 digit voltage and current displays. |
| TTL |
TTL compatible high voltage enable. |
| GE9 |
RS-232 control and monitor. |
Models
Click on the model number below to request a quote and
for complete ordering part number.
Series PG Models
Series PG-LR Models (same panel and stack heights as above)
Outline Drawing

|