WR Series
250 Watt Regulated
High Voltage
DC Power Supplies
|

PDF Print Version
HTML Print Version
|
 |
| Models from 0 to 85 kV through 0 to 125 kV. |
|
| Fully compliant with the European harmonized EMI
directive, EN50082-2, and with the low voltage (safety) directive, 73/23/EEC. |
|
- Up to 125 kV
- 5.25 Inch Panel Height
- Laboratory Performance
- Enhanced Features
|
The WR Series is a natural extension to our lower voltage ER Series...providing
high voltage ranges to 125 kV in only 5.25 inches of panel height. Three control panel configurations are
available... analog, digital, or blank. Together with a full complement of standard remote controls, this
makes the WR Series compatible with most applications and environments. And all this powerful performance
is available at an affordable price.
Features
Constant Voltage/Constant Current Operation. Automatic crossover from
voltage or current regulation modes is provided as dictated by load conditions.
Low Ripple. Ripple is less than 0.05% of rated voltage at full load.
Tight Regulation. Voltage regulation is better than 0.005%, line or
load, and current regulation is better than 0.05% from short circuit to rated voltage.
Fast Transient Response. The supply responds to a 50% load transient
in less than 3 milliseconds.
Front Panel Controls (Analog and Digital Versions.) Separate 10-turn
controls with locking vernier dials are used to set voltage and current levels. A high voltage enable/disable
switch and an AC power On/Off switch complete the panel controls. L.E.D.'s indicate when high voltage is on
and whether the supply is operating in a voltage or current regulating mode. For the blank panel version, only
a power On/Off switch is provided.
Remote Control Facilities. As standard, all WR Series supplies provide
output voltage and current program/monitor terminals. TTL high voltage enable/disable, safety interlock terminals,
and a +10 volt reference source.
Small Size and Weight. WR Series power supplies consume only 5.25 inches
of panel height. Weight is 30 pounds typical.
Air Insulated. The WR Series features "air" as the primary
dielectric medium. No oil or encapsulation is used to impede serviceability or increase weight.
Warranty. Standard power supplies are warranted for three years; OEM
and modified power supplies are warranted for one year. A formal warranty statement is available.
Specifications
(From 5% to 100% rated voltage. All units operate down to zero output with
very slight degradation of performance.)
Input: 105-125 V RMS, 48-63 Hz single phase, <6 A. Connector per IEC
320 with mating line cord.
Efficiency: Typically 85% at full load.
Output: Continuous, stable adjustment, from 0 to rated voltage or current
by panel mounted 10-turn potentiometers with 0.05% resolution, or by external 0 to 10V signals is provided.
Linearity is <1% of rated. Accuracy is 1% of rated + 1% of setting. Repeatability is <0.1% of rated.
Stored Energy: 11 joules, max.
Voltage Regulation: <0.005% line and load.
Ripple: <0.05% RMS of rated voltage at full load.
Current Regulation: <0.05% from short circuit to rated voltage at any
set current.
Voltage Monitor: 0 to +10 V DC for zero to rated voltage. Accuracy, 1% of
reading + 1% of rated voltage.
Current Monitor: 0 to +10 V DC for zero to rated current. Accuracy, 1% of
reading + .05% of rated current.
Stability: 0.01% per hour after 1/2 hour warm-up, 0.05% per 8 hours.
Voltage Rise/Decay Time Constant: Typically 400 ms rise or decay time
constant for 125 kV model, using HV on/off or remote voltage control, with 25% resistive load.
Temperature Coefficient: 0.01%/°C.
Ambient Temperature: -20 to +40°C operating, -40 to +85°C storage.
Polarity: Positive, negative, or reversible with respect to chassis ground.
Protection: Automatic current regulation protects against all overloads,
including arcs and short circuits. Fuses, surge-limiting resistors, and low-energy components provide ultimate
protection.
Accessories: Detachable 8-foot shielded HV Coaxial cable (see Model Chart
for cable type) and 6-foot detachable line cord provided.
Remote controls: Common, +10 V reference, interlock, current monitor,
current program, voltage monitor, voltage program, TTL, and ground, provided on a rear mounted terminal block.
External Interlock: Open off, closed on. Normally latching except for
blank front panel version where it is non-latching.
HV Enable/Disable: 0-1.5 V off, 2.5-15 V on.
Options
| Symbol |
Description |
| 100 |
100 V input, rated 90-110 V RMS, 48-63 Hz. |
| 220 |
220 V input, rated 200-264 V RMS, 48-63 Hz. |
| 400 |
48-420 Hz, available on standard model and
options 100 and 220. |
| DM |
3-1/2 digit LCD panel meters. |
| NC |
Blank front panel (power switch only). |
| CT |
Current trip. Power supply trips off when the
load current reaches the programmed level. This option has a rear panel switch that selects either “trip”
operation or current limiting. |
| ZR |
Zero start interlock. Voltage control must be at
zero before accepting an enable signal. |
| SS |
Slow start ramp of up to 30 seconds
available. Specify time. |
| 5VC |
0-5V Voltage and Current Program/Monitor. |
| GE9 |
RS-232 control and monitor. |
Models
Click on the model number below to request a quote and
for complete ordering part number.
Outline Drawing

|