WX Series
1000 Watt Regulated
High Voltage
DC Power Supplies
|

PDF Print Version
HTML Print Version
|
 |
| Models from 0 to 1 kV through 0 to 75 kV. |
|
| Fully compliant with the European harmonized EMI
directive, EN50082-2, and with the low voltage (safety) directive, 73/23/EEC. |
|
- Supplies Up To 75 kV
- 5.25 Inch Panel Height
- Laboratory Performance
- Enhanced Features
|
The WX Series provides 1000 watts of output power with voltage ranges up to
75 kV in a rack-panel height of only 5.25 inches, and weighs less than 30 pounds. Standard models have dual
analog voltage and current meters. As an option, WX is available with dual digital meters or with a blank
front panel for OEM/system applications. Local front panel controls and full remote controls are standard.
Features
Pulse-Width Modulation. Off-the-line pulse-width modulation provides high
efficiency and a reduced parts count for improved reliability.
Air Insulated. The WX Series features "air" as the primary
dielectric medium. No oil or encapsulation to impede serviceability or increase weight.
Constant Voltage/Constant Current Operation. Automatic crossover from
constant-voltage to constant-current regulation provides protection against overloads, arcs, and short circuits.
Low Ripple. Ripple is less than 0.05% of rated voltage at full load.
Tight Regulation. Voltage regulation is better than 0.005% for allowable
line variations and 0.01% + 1 mV/mA for load variations. Current regulation is better than 0.05% from short
circuit to rated voltage.
Front Panel Controls (Analog and Digital Versions). Separate 10-turn
controls with locking vernier dials are used to set voltage and current levels. A high voltage enable switch
and an AC power on/off switch complete the panel controls. L.E.D.'s indicate when high voltage is on, the
output polarity, and whether the supply is operating in a voltage or current regulating mode. For the blank
panel version, only a power on/off switch is provided on the panel.
Warranty. Standard power supplies are warranted for three years; OEM
and modified power supplies are warranted for one year. A formal warranty statement is available. Small Size
and Weight. WX Series power supplies occupy only 5.25 inches of panel height. Net weight is less than 30 pounds.
Specifications
(From 5% to 100% rated voltage. All units operate down to zero output with
very slight degradation of performance.)
Input: 198-242 V RMS, 48-63 Hz, single-phase, <9.5A. Connector per
IEC 320 with mating line cord terminated with NEMA 6-15 plug.
Efficiency: Typically 83% at full load.
Output: Continuous,stable adjustment, from 0 to rated voltage or current
by panel mounted 10-turn potentiometers with 0.05% resolution, or by external 0 to 10V signals is provided.
Linearity is <1% of rated. Accuracy is 1% of rated + 1% of setting. Repeatability is <0.1% of rated.
Stored Energy: 6 Joules, maximum, up to 50 kV. 9 Joules, maximum,
60 and 75 kV.
Voltage Regulation: <0.005% for the specified line variations and
0.01% + 1 mV/mA for load variations.
Ripple: <0.05% of rated voltage + 0.5 V RMS at full load.
Current Regulation: <0.05% from short circuit to rated voltage at
any set current.
Voltage Monitor: 0 to + 10 V DC, equivalent to zero to rated voltage.
Accuracy, 1% of reading + 1% of rated voltage.
Current Monitor: 0 to + 10 V DC, equivalent to zero to rated current.
Accuracy, 1% of reading + 0.05% of rated current.
Stability: 0.01% per hour after 1/2 hour warm-up. 0.05% per 8 hours.
Voltage Rise/Decay Time Constant: Typically 50 ms rise or decay time
constant, using HV on/off or remote voltage control, with a 50% resistive load.
Temperature Coefficient: 0.01%/ degree C.
Ambient Temperature: -20 to +45 degrees C, operating; -40 to +85
degrees C, storage.
Polarity: Positive, negative, or reversible with respect to chassis
ground.
Protection: Automatic current regulation protects against all overloads,
including arcs and shorts. Fuses, surge-limiting resistors, and low-energy components provide ultimate protection.
Accessories: Detachable 8-foot shielded HV coaxial cable (see Models
chart for cable type) and 6-foot detachable line cord with NEMA 6-15 plug are provided.
Remote Controls: Common, +10 V reference, interlock, current monitor,
current program, voltage monitor, voltage program, HV enable/disable, and ground provided on a rear panel
mounted terminal block.
External Interlock: Open off, closed on. Normally latching except on
blank panel version where it is non-latching.
HV Enable/Disable: 0-1.5 V off, 2.5-15 V on.
Options
| Symbol |
Description |
| 240 |
216-264 V input, 48-63 Hz |
| DM |
3-1/2 digit LCD panel meters. |
| NC |
Blank front panel, power switch only. |
| CT |
Current trip. Power supply trips off when the
load currentreaches the programmed level. This option has a rear panel switch that selects either
"trip" operation or current limiting. |
| ZR |
Zero start interlock. Voltage control,
local or remote, must be at zero before accepting an enable signal. |
| SS |
Slow start ramp of up to 30 seconds
available. Specify time. |
| 5VC |
0-5 V voltage and current programming. |
| GE9 |
RS-232 control and monitor. |
Models
Click on the model number below to request a quote and
for complete ordering part number.
Outline Drawing

|